8
15. If supplied dismounted for shipping, assemble the lower
part of the hood with the internal blower housing:
a. Remove the grease filter (See also Care & Use
section - Charcoal filter).
b. Rest the internal blower housing on a flat surface and
thread completely the lower part of the hood onto it.
c. Connect all cables:
d. Fasten the hood to the motor unit using 8 screws from
the bottom.
16. Hang hood with the 2 mounting hooks.
WARNING
Excessive Weight Hazard - Use two or more people to
move and install range hood. Failure to do so can result
in back or other injury.
17. Level the appliance, using a carpenters level across
bottom of hood with leveling screws in mounting hooks.
18. Secure hood with 1 screw on bottom.
19. Connect ducting to transition. Seal with duct tape.
Do not use duct smaller than the transition.
For Ductless - recirculating - installations only:
provide and install a duct to connect hood transition to
deflector (The deflector is available as an extra kit).