Vista de pagina 32
1. Remove filters
2. Remove cover from junction box to
gain access to electrical wiring.
3. If using a cable lock, pry open the
desired electrical knockout either on
top or back of hood. Feed the wires
through the cable lock. Some local
codes require the use of a cable lock,
check your local codes.
4. If using hood in air recirculating
mode skip steps 4 and 5.
Pry open desired ducting knock-out
either on top or back of hood.
5. Remove starting collar from inside
hood body and secure 3-1/4” x 10”
rect. starting collar to the top or rear
duct opening using (10) M3.5x12
screws.
5. Remove starting collar from inside
hood body and secure 6” round start-
ing collar to the top duct opening using
(10) M3.5x12 screws.